In this paper, the infrared stimulated luminescence (IRSL) property of naturally corroded aluminum and its possible applications in retrospective dosimetry have been briefly studied. Results are interesting, in particular with regard to the efforts of finding new and widely available materials for accident dosimetry. For aluminum corrosion, the dose response was found to be approximately linear between 2–80 Gy and to reach saturation before 300 Gy. The signal also showed good repro-ducibility without significant fading over storage durations of up to four mounts at room temperature. In addition to the luminescence, the corrosion samples were also analysed by X-ray Fluorescence (XRF) and X-ray Diffraction (XRD), but conclusive identification of the luminescent phase could not be made. It is concluded that the IRSL signals of this material can be favourable for dosimetry research.
REFERENCES(14)
1.
Akselrod MS, Lucas AC, Polf JC and McKeever SWS, 1998. Optically stimulated luminescence of Al2O3. Radiation Measurements 29(3–4): 391–399, DOI 10.1016/S1350-4487(98)00061-4. http://dx.doi.org/10.1016/S135....
Bøtter-Jensen L and Murray AS, 2001. Optically stimulated lumines-cence techniques in retrospective dosimetry. Radiation Physics and Chemistry 61(3–6): 181–190, DOI 10.1016/S0969-806X(01)00239-0. http://dx.doi.org/10.1016/S096....
Göksu HY, Bailiff IK and Mikhailik VB, 2003. New approaches to retrospective dosimetry using cementitious building materials. Ra-diation Measurments 37(4–5): 323–327, DOI 10.1016/S1350-4487(03)00005-2. http://dx.doi.org/10.1016/S135....
McKeever SWS, 2001. Optically stimulated luminescence dosimetry. Nuclear Instruments and Methods B in Physics Research Section 184(1–2): 29–54, DOI 10.1016/S0168-583X(01)00588-2. http://dx.doi.org/10.1016/S016....
Meriç N, Kosal M, Atlıhan MA and Yüce ÜR, 2008. OSL properties of anthropological bone and tooth. Radiation Physics and Chemistry 77(6): 685–689, DOI 10.1016/j.radphyschem.2008.01.006. http://dx.doi.org/10.1016/j.ra....
Yüce UR, Meriç N, Atakol O and Yaşar F, 2010. Dose response of hydrazine-deproteinated tooth enamel under blue light stimula-tion. Radiation Measurements, 45(7): 797–800, DOI 10.1016/j.radmeas.2010.03.005. http://dx.doi.org/10.1016/j.ra....
Spooner NA, Aitken MJ, Smith BW, Franks M and McElroy C, 1990. Archaeological dating by infrared-stimulated luminescence using a diode array. Radiation Protection Dosimetry 34(1–4): 83–86.
Truscott AJ, Duller GAT, Bøtter-Jensen L, Murray AS and Wintle AG, 2000. Reproducibility of optically stimulated luminescence meas-urements from single grains of Al2O3:C and annealed quartz. Ra-diation Measurements 32(5–6), 447–451, DOI 10.1016/S1350-4487(00)00080-9. http://dx.doi.org/10.1016/S135....
Yukihara EG, Mittani J, McKeever SWS and Simon SL, 2007. Optical-ly Stimulated Luminescence (OSL) of dental enamel for retrospec-tive assessment of radiation exposure. Radiation Measurements 42(6–7), 1256–1260, DOI 10.1016/j.radmeas.2007.05.038. http://dx.doi.org/10.1016/j.ra....
We process personal data collected when visiting the website. The function of obtaining information about users and their behavior is carried out by voluntarily entered information in forms and saving cookies in end devices. Data, including cookies, are used to provide services, improve the user experience and to analyze the traffic in accordance with the Privacy policy. Data are also collected and processed by Google Analytics tool (more).
You can change cookies settings in your browser. Restricted use of cookies in the browser configuration may affect some functionalities of the website.